ENGLISH V2_2018
TECHNICAL DATA Opening 110º MESUCO 143 rapid
> CH.2 HINGES AND LIFTING SYSTEMS
TECHNICAL DATA
5
MESUCO 143 RAPID Opening 110º
Full overlay
Calculation of the height of the plate
C = B + K - D
K = Constant =
15mm
Partial Overlay
Calculation of the height of the plate
C = B + K - D
K = Constant =
10mm
Half overlay
Calculation of the height of the plate
C = B + K - D
K = Constant =
5mm
Full inset*
Calculation of the height of the plate
C = B + K + D
K = Constant =
-2mm
* The position to fix the base has to be moved back a distance equal to the door thickness + 1mm
Lateral door displacement (F).
mm.
mm B 16 17 18 19 20 21 22 23 24 3 0,6 0,8 1,1 1,5 2 2,6 3,3 4 4,9 4 0,6 0,8 1,1 1,4 1,8 2,4 3 3,7 4,5 5 0,6 0,8 1 1,4 1,7 2,2 2,7 3,4 4,1 6 0,5 0,7 1 1,3 1,7 2,1 2,6 3,2 3,8 Door thickness
2500
18-24kg
2000
12-16kg
1500
7-11kg
1000
3,5-6kg
500
Vertical adjustment It depends on mounting plate model
Lateral adjustment -0mm +4mm
Frontal adjustment -1,5mm +1,5mm
Hinges / Door